Contact Download Experience Services Products Profile
HOME HOME  Tuesday, September 07, 2010  
PRODUCTS
 AC SOLUTION
  AC Power Distribution
  AC Power Backup
  AC Voltage Stabilizer
  AC Power Inverter
  AC PF Correction
  AC Generator Diesel
 DC SOLUTION
  DC Power Distribution
  DC Power Rectifier
  DC Circuit Protection
  DC-DC Converter
 CONTROL SYSTEM SOLUTION
  Charge Discharge System
  SMS Alarm Module
  ATS/AMF Control
  ATS/ABCF Control 
  Solar Charge Controller
  IPM Control
  Varifan & Dustrap
  MPPT Solar Charge Control
 RENEWABLE ENERGY
  Hybrid Power System
  PV Solar Module
  Standalone solar system


MEMBER LOGIN
Userid
Pass
   

Membership Registration
  
Charge Discharge System

SOC base Charge-Dischargetm System

"Efficient your generator fuel consumption using our smart charge-discharge control"

Cost savings and increased reliability this is what Caturmukti Charge Discharge™ Power System is all about. By combining proven power generation with advanced control systems, Charge-Discharge™ can be seamlessly integrated in many applications, dramatically reducing the overall costs and increasing system reliability.

The right choice for Remote BTS, where:

  • Poor quality of Power Utility
  • No Mains (PLN)
 
 

System Overview:
SOC (State Of Charge) base system should be read as a percentage estimate of how full the ampere hours (ah) battery is.

The estimate is based on the amp hour balance counter. This counter keeps a running balance of amp hours input versus amp hours output. At the controller the SOC display shows this balance as a percentage of the battery size.

To prevent battery damage due to over-discharge, the controller has an internal function designed to turn on the engine to charge battery if the battery voltage falls too low.

Specifications:

1. Charge Discharge Controller :

  • System Voltage : 12 VDC, 24 VDC, 48 VDC
    • Battery Capacity : Max. 2000 ah
    • DC Current : Max. 200 Amp.
    • ATS Charging Current : Max. 100 Amp. at 220 VAC/380 VAC
    • Supply Current : 20 mA
    • Ambient Temp. : -15 C – 50 C

 

2. Generator Control system :

·         Complete with Fuel Pump Control

·         Automatic remote start system

·         Alarm Failure : Genset Fail, High Temp, Low Oil Press and Low Battery Voltage via dry contact relais.

·         Operating VDC limits: (3.3VDC min.- 30VDC max.)

·         Standby current draw: 12mA

·         Operating current draw: 175mA

·         Reverse polarity protected

·         Speed sensing input accepts:

o       Magnetic pickup

o       Engine alternator

o       Flywheel alternator

o       Generator AC output directly

·         Speed sensing maximum rating: Withstands Line voltage (300 VAC)

·         Operating temperature range: -40 C to +85  C

·         Operating humidity range: 0 - 95% non-condensing

Please Contact Us for demo and presentation.