Contact Download Experience Services Products Profile
HOME HOME  Tuesday, September 07, 2010  
PRODUCTS
 AC SOLUTION
  AC Power Distribution
  AC Power Backup
  AC Voltage Stabilizer
  AC Power Inverter
  AC PF Correction
  AC Generator Diesel
 DC SOLUTION
  DC Power Distribution
  DC Power Rectifier
  DC Circuit Protection
  DC-DC Converter
 CONTROL SYSTEM SOLUTION
  Charge Discharge System
  SMS Alarm Module
  ATS/AMF Control
  ATS/ABCF Control 
  Solar Charge Controller
  IPM Control
  Varifan & Dustrap
  MPPT Solar Charge Control
 RENEWABLE ENERGY
  Hybrid Power System
  PV Solar Module
  Standalone solar system


MEMBER LOGIN
Userid
Pass
   

Membership Registration
  
ATS/AMF Control

CMP SmartPower-Universal SeriesTM

ATS (Automatic Transfer Switch)/AMF (Automatic Mains Failure)

The Problem: the damages caused by voltage failure and low power quality, even if for a short time, in terms of lost communication are very well known.

The Goal: to improve the continuity of electricity supply and the efficiency of the generator set start up and maintenance via the use of an intelligent device.

The Solution: ATS/AMF with high reliability, well protected, dual mode operation, and remote operation and monitoring.

System Key Features:

  • High Reliability and Proven Design
  • Wall Mounted Compact Enclosure (w600xh800xd210mm)
  • Dual Operation Mode (Auto/Manual)
  • Remote operation and monitoring via RS485,RS232,LAN,Ethernet)
  • Controller with wide range operating voltage (6.7-35 VDC)
  • Minimize the number of relay (only 3 Relay DC)
  • No AC Relay (avoid from mains lightning surge)
  • To prevent premature damage, coils are not energized continuously
  • All controller contacts are protected from surges by built in varistors
System Specifications:
  • Power Capacity : 5 kVA - 1 MVA
  • 1 phase or 3 phase system
  • Voltage operation range 220VAC/380VAC
  • System configuration :
    • Type 1+0 (Main Supply + Genset).
    • Type 1+1 (Main Supply + Genset 1 + Genset 2)
    • Type 2+1 (Genset 1 + Genset 2 + Genset 3)
  • Prime or stand by of Peak Saving Electrical Power Supply
 
ATS Key Features:
  • Automatic Transfer Switch (ATS) :
    • No operating voltage required after change over (Mechanical latch mechanism)
    • High speed change over (13 ms)
    • Contact pressure is kept by leaf spring (no change in contact due to voltage fluctuations)
    • Switching durability (Mechanical=50,000 times & Electrical=250,000 times)
    • Manual and automatic operation
Controller Key Features:
 
  • Controller will protect system from:
    • Under and Over Voltage
    • Under and Over Frequency
    • Excessive Voltage Hysterisis
    • Unbalance Voltage
    • Low oil pressure
    • High engine temperature
  • Controller Electrical measurement:
    • Voltage (p-p,p-n) Mains and Generator
    • Current Mains and Generator
    • Power (active, reactive and apparent)
    • Frequency (45..65 Hz)
    • Energy (active and reactive)
    • Power Factor
  • Controller Special Features:
    • Generator protection (overload and short circuit)
    • 12 digital inputs all programmable
    • 2 engine hour counter (one of these visible and reset-able only from PC)
    • Maintenance interval setting
    • Safety copy of parameters in flash memory
    • Information page that can be filled with free user data
    • Personalised logo on LCD screen
    • “HELP” messages
Copyright © 2005 Caturmukti Pratama. All right reserved.   
Please send comment to webmaster